Call us on +44 (0) 1564 200 826

Microorganisms inactivated by UV-C

Microorganisms are found throughout our environment. Many are harmless, but others cause infection, contaminate products, drive food spoilage or undermine the hygiene of production areas and clinical spaces. For food manufacturers and healthcare providers, controlling them is a daily operational, regulatory and reputational concern.

UV-C disinfection reduces microbial contamination in air, on exposed surfaces and in suitable fluids, without chemicals or residues. It works in seconds to minutes, and the dose delivered can be measured and recorded, which makes it straightforward to evidence in audits.

It is used across food manufacturing, healthcare, pharmaceuticals, laboratories and building services.

Understanding microorganisms and UV-C disinfection

Ultraviolet light is divided into three bands: UV-A (315 to 400 nm), UV-B (280 to 315 nm) and UV-C (100 to 280 nm). UV-C is the germicidal band. Germicidal lamps typically emit around 254 nm, a wavelength that microbial DNA and RNA absorb very effectively.

When a microorganism absorbs UV-C, its genetic material is damaged. The organism may still be physically present, but it can no longer replicate or cause infection. Because the mechanism is physical rather than chemical, UV-C acts on a broad range of organisms at once, and microorganisms do not build resistance to it in the way they can to some chemical disinfectants.

How well it works depends on the organism, the wavelength, the delivered dose and how effectively the radiation reaches the target.

Arden Ultraviolet supplies UV-C disinfection equipment and supports organisations in assessing how artificial UV sources can be built into their processes. Explore our UV-C disinfection equipment, or contact us to discuss your requirements.

What types of microorganisms can UV-C inactivate?

UV-C can inactivate bacteria, viruses, moulds, yeasts and certain other microorganisms when an appropriate dose reaches them. Susceptibility varies considerably, though, and a system that is effective against one organism may not achieve the same reduction against another.

As a general pattern in the published data below, most vegetative bacteria and many viruses are inactivated by relatively low doses, while bacterial spores, some viruses and some fungal spores need considerably more. The sections below introduce each group, the areas where it matters most, and where to find more detail.

Bacteria

Bacteria are single-celled microorganisms found in soil, water, air, on surfaces and in living organisms. Some are beneficial, while others cause infections, contaminate food or cause product deterioration.

In food manufacturing, bacterial contamination can affect raw ingredients, processing equipment, conveyor belts, packaging and ready-to-eat products. In healthcare, bacteria can be linked to contaminated surfaces, equipment and airborne transmission.

MicroorganismCommon areas of concern
Listeria monocytogenesReady-to-eat foods, chilled meals, food processing
Escherichia coli (E. coli)Fresh produce, meat, water, healthcare
SalmonellaPoultry, eggs, meat, confectionery and other foods
Staphylococcus aureusHealthcare, food handling, contaminated surfaces
Pseudomonas aeruginosaHealthcare, wet environments, water systems
Legionella pneumophilaBuilding water systems and aerosol-generating equipment
CampylobacterPoultry, meat processing, food hygiene
Clostridium speciesFood processing, soil, selected healthcare environments
Enterococcus speciesHealthcare, wastewater and environmental hygiene

UV-C can provide an additional control for suitable air, water or exposed-surface applications. The right approach depends on the organism and the contamination route. Treating the air, for example, will not control bacteria that are already established on equipment or within residues.

Viruses

Viruses are infectious agents that need host cells to replicate. Depending on the virus, they can spread through respiratory particles, contaminated surfaces, bodily fluids, water or other routes. UV-C damages viral genetic material and interferes with replication, and the dose needed varies with the virus, the surrounding medium and the treatment conditions.

VirusCommon areas of concern
Influenza virusesHealthcare, care homes, occupied buildings
SARS-CoV-2Healthcare, workplaces, indoor environments
NorovirusHealthcare, hospitality, food handling
Hepatitis A virusFood handling, contaminated water and produce
RotavirusHealthcare, childcare, contaminated environments
AdenovirusHealthcare, communal environments, water

Depending on your risk assessment, UV-C air disinfection can help reduce susceptible airborne microorganisms in suitable environments, and enclosed surface-disinfection systems may suit selected items and equipment.

UV-C must never be used to disinfect people, hands or skin. Equipment must be designed and operated to prevent hazardous exposure to workers and occupants.

Moulds and fungi

Moulds and other fungi grow on organic materials and can release spores that travel through the air. In buildings, mould is often associated with excess moisture, condensation, poor ventilation or water damage. In food production, moulds cause spoilage and can affect shelf life, quality and waste.

Some moulds can produce mycotoxins. Inactivating fungal cells or spores with UV-C should not be assumed to destroy toxins that are already present.

MicroorganismCommon areas of concern
Aspergillus speciesBuildings, ventilation systems, food and stored materials
Penicillium speciesFruit, chilled storage, food processing
Cladosporium speciesIndoor air, damp buildings, ventilation
Alternaria speciesAgriculture, produce, indoor environments
Rhizopus speciesFruit and vegetable spoilage, food storage

Fungal spores are often more resistant to UV-C than vegetative bacteria, and dose requirements vary widely between species and strains. UV-C may be used in suitable air-handling systems, cold stores and selected exposed-surface applications, and its effectiveness depends on spore resistance, exposure, shadowing and the condition of the treated surface.

UV-C is not a substitute for addressing the cause of mould growth. Moisture control, cleaning, repairs and appropriate ventilation remain essential.

Yeasts

Yeasts are single-celled fungi. Some are useful in brewing and baking, while others cause unwanted fermentation, spoilage or contamination in food and beverage production.

MicroorganismCommon areas of concern
Saccharomyces speciesBrewing, baking and fermentation
Zygosaccharomyces speciesHigh-sugar foods, syrups and beverages
Candida speciesHealthcare and selected production environments

In suitable applications, UV-C can be assessed for treating process air, exposed equipment surfaces, packaging or certain fluids. Treatment must be appropriate for the product and process, particularly where beneficial yeasts are used deliberately in fermentation.

Other microorganisms

Other organisms, including protozoa and some parasites, can be relevant to water treatment, public health and specific industrial applications. Their susceptibility varies, and not every organism can be controlled with the same equipment or dose.

GroupExamplesCommon areas of concern
ProtozoaGiardia, CryptosporidiumDrinking water and water treatment
Parasitic organismsSelected helminths and parasite life stagesFood safety, agriculture and water
Bacterial sporesSpores of selected Bacillus and Clostridium speciesFood production, laboratories and healthcare

Water disinfection needs particular attention to water quality, UV transmission, flow rate, reactor design and validated performance. Surface and air treatment cannot be assumed to control organisms in water or within a product.

Understanding UV-C dose

UV-C effectiveness depends on dose, also called fluence. Dose is the intensity of UV-C reaching the target (irradiance) multiplied by the time of exposure:

UV-C dose (J/m²) = irradiance (W/m²) × exposure time (seconds)

One watt delivers one joule per second, so a target receiving 1 W/m² for 10 seconds receives a theoretical dose of 10 J/m². This assumes irradiance stays constant at the target throughout. Many publications quote dose in millijoules per square centimetre (mJ/cm²), and 10 J/m² equals 1 mJ/cm².

What is a log reduction?

A log reduction describes how much a population of viable microorganisms is reduced after treatment.

Log reductionPercentage reductionRemaining from 1,000,000 organisms
1-log90%100,000
2-log99%10,000
3-log99.9%1,000
4-log99.99%100
5-log99.999%10
6-log99.9999%1

These are mathematical examples, not a prediction of how any particular UV-C system will perform. A higher log reduction generally needs a higher dose, but the relationship must be established for the target organism and application rather than assumed to be the same for all organisms.

What is a D90 value?

The D90 value is the dose needed to inactivate 90% of a microbial population, which is a 1-log reduction. It is the standard way to compare how sensitive different microorganisms are to UV-C, and it is the figure used in the tables below.

A worked example

Suppose you want a 3-log (99.9%) reduction of Listeria monocytogenes on a surface. The published D90 is 156 J/m², so the target dose is roughly 3 × 156 = 468 J/m². At an irradiance of 10 W/m², that is about 47 seconds of exposure.

For Salmonella enteritidis (D90 of 10 J/m²), the same reduction needs around 30 J/m², or about 3 seconds at the same irradiance.

This is a simplified illustration that assumes a consistent, straight-line response, which real conditions do not always follow. It does show why systems should be designed around the most resistant organism you need to control: where several organisms are targeted, the one with the highest dose requirement sets the design.

Dose requirements for key food and healthcare organisms

The following snapshot shows how widely dose requirements vary across organisms that matter most in food and healthcare. The 3-log figure is simply three times the D90, for illustration.

MicroorganismD90 (1-log)Illustrative 3-logMedium
Salmonella enteritidis10 J/m²30 J/m²Surface
Legionella pneumophila5 J/m²15 J/m²Surface
Influenza A virus19 J/m²57 J/m²Air
E. coli55 J/m²165 J/m²Surface
Pseudomonas aeruginosa55 J/m²165 J/m²Surface
Staphylococcus aureus66 J/m²198 J/m²Surface
Bacillus subtilis spores149 J/m²447 J/m²Air
Listeria monocytogenes156 J/m²468 J/m²Surface
Adenovirus type 2400 J/m²1,200 J/m²Surface

Full UV-C dose table for bacteria, spores and viruses

The tables below list D90 values from independent research published over many decades, covering bacteria, bacterial spores and viruses in air and on surfaces. Where an organism appears more than once, the entries come from different studies and test conditions.

Vegetative bacteria

MicroorganismD90 (J/m²)MediumSource
Acinetobacter baumannii18SurfaceRastogi 2007
Bacillus subtilis14AirNakamura 1987
Burkholderia cepacia22AirFletcher 2004
Corynebacterium diphtheriae33SurfaceSharp 1939
Escherichia coli (E. coli)55SurfaceHollaender 1955
Escherichia coli (E. coli)11AirKoller 1939
Francisella tularensis288AirBeebe 1959
Haemophilus influenzae38SurfaceMongold 1992
Halobacterium sp. NRC-125SurfaceCrowley 2006
Legionella bozemanii15SurfaceKnudson 1985
Legionella dumoffi24SurfaceKnudson 1985
Legionella gormani26SurfaceKnudson 1985
Legionella jordanis11SurfaceKnudson 1985
Legionella longbeach11SurfaceKnudson 1985
Legionella micdadei15SurfaceKnudson 1985
Legionella oakridgensis22SurfaceKnudson 1985
Legionella pneumophila5SurfaceKnudson 1985
Legionella wadsworthii4SurfaceKnudson 1985
Listeria monocytogenes156SurfaceKim 2002
Micrococcus candidus61SurfaceHollaender 1955
Micrococcus piltonesis81SurfaceRentschler 1941
Micrococcus sphaeroides100SurfaceRentschler 1941
Mycobacterium bovis BCG22SurfaceCollins 1971
Mycobacterium bovis BCG33AirKo 2000
Mycobacterium parafortuitum46AirPeccia 2001
Mycobacterium phlei63AirRiley 1976
Mycobacterium smegmatis12AirGillis 1974
Mycobacterium tuberculosis11SurfaceCollins 1971
Mycobacterium tuberculosis5AirRiley 1976
Mycoplasma arthritidis7SurfaceFurness 1977
Mycoplasma fermentans9SurfaceFurness 1977
Mycoplasma hominis7SurfaceFurness 1977
Mycoplasma orale type 111SurfaceFurness 1977
Mycoplasma orale type 26SurfaceFurness 1977
Mycoplasma pneumoniae8SurfaceFurness 1977
Mycoplasma salivarium11SurfaceFurness 1977
Neisseria catarrhalis44SurfaceRentschler 1941
Nocardia asteroides280SurfaceChick 1963
Phytomonas tumefaciens44SurfaceRentschler 1941
Proteus vulgaris30SurfaceRentschler 1941
Pseudomonas aeruginosa55SurfaceHollaender 1955
Pseudomonas aeruginosa4AirSharp 1940
Pseudomonas fluorescens35SurfaceRentschler 1941
Pseudomonas fluorescens3Airvan Osdell 2002
Salmonella enteritidis10SurfaceCollins 1971
Salmonella typhi21SurfaceSharp 1939
Sarcina lutea197SurfaceRentschler 1941
Serratia indica209AirHarstad 1954
Serratia marcescens22SurfaceSharp 1939
Serratia marcescens115AirKo 2000
Shigella paradysenteriae17SurfaceSharp 1939
Spirillum rubrum44SurfaceRentschler 1941
Staphylococcus albus33SurfaceRentschler 1941
Staphylococcus albus (1)23AirRentschler 1942
Staphylococcus albus (2)52AirRentschler 1942
Staphylococcus aureus66SurfaceGates 1934
Staphylococcus aureus20AirNakamura 1987
Staphylococcus epidermidis29Airvan Osdell 2002
Streptococcus agalactiae5AirLuckiesh 1949
Streptococcus haemolyticus22SurfaceSharp 1939
Streptococcus pneumoniae468SurfaceGritz 1990
Streptococcus pyogenes4SurfaceLidwell 1950
Streptococcus pyogenes1AirLuckiesh 1949
Streptococcus viridans20SurfaceSharp 1939

Bacterial spores

MicroorganismD90 (J/m²)MediumSource
Bacillus anthracis spores743SurfaceKnudson 1986
Bacillus atrophaeus (B. globigii) spores144AirEPA 2006
Bacillus cereus spores408SurfaceBenoit 1990
Bacillus megatherium273SurfaceHercik 1937
Bacillus subtilis spores149AirKe 2009

Viruses

MicroorganismGenomeD90 (J/m²)MediumSource
AdenovirusdsDNA59AirWalker 2007
Adenovirus type 2dsDNA400SurfaceDay 1974
Adenovirus type 40dsDNA300SurfaceMeng 1996
Adenovirus type 41dsDNA240SurfaceMeng 1996
Bacteriophage MS2dsRNA61AirWalker 2007
Bacteriophage MS2dsRNA4AirTseng 2005
Coliphage PRD1dsDNA87SurfaceMeng 1996
Coliphage T7dsDNA10AirTseng 2005
Coliphage X-174dsDNA4AirTseng 2005
CoronavirusssRNA3AirWalker 2007
CoxsackievirusssRNA21AirJensen 1964
Human cytomegalovirusdsDNA658SurfaceAlbrecht 1974
Influenza A virusssRNA19AirJensen 1964
Newcastle disease virusssRNA16SurfaceRubin 1959
Phage phi 6dsRNA7AirTseng 2005
PoliovirusdsRNA44SurfaceMa 1994
Poliovirus type 1dsRNA41SurfaceMeng 1996
Rauscher murine leukemia virusssRNA959SurfaceStull 1976
Rous sarcoma virus (RSV)ssRNA200SurfaceRubin 1959
SARS-CoV-2 (coronavirus)ssRNASee noteSurfaceGriffiths, Boston University
Sindbis virusssRNA62AirJensen 1964
S. aureus phagessDNA82SurfaceGates 1934
Vaccinia virusssDNA15AirJensen 1964

SARS-CoV-2 note: In research led by Dr Anthony Griffiths at Boston University School of Medicine, a UV-C dose of 50 J/m² reduced SARS-CoV-2 by 99%. The data indicates that 220 J/m² achieves a 99.9999% reduction.

Important: These figures are indicative values from independently published research, not guaranteed treatment requirements. Results depend on the strain, test medium, wavelength, method and exposure conditions, and other sources report different values for some of the same organisms. The tables should not be used on their own to specify equipment, set exposure times or claim a particular reduction in a production facility. Where a defined microbial reduction is required, the system and process should be validated under representative operating conditions.

Why the dose in your facility differs from the dose in the table

Published D90 values come from controlled laboratory tests. In a working facility, the dose that reaches a microorganism depends on several things:

  • Irradiance and distance. UV-C intensity falls sharply with distance from the lamp, so positioning matters as much as lamp power. A lamp’s electrical rating alone cannot establish the reduction achieved in a real installation.
  • Exposure time. Conveyor speeds, cabinet cycle times and air flow rates all determine how long the target is exposed.
  • Lamp output and ageing. Output declines over a lamp’s life, so a system sized for day one may under-deliver later.
  • Surface and shadowing. UV-C travels in straight lines. Textured, uneven or shadowed surfaces receive less dose, and dust, films and organic soiling can shield microorganisms.
  • Airflow, temperature and humidity. For air disinfection, conditions inside the unit affect the dose delivered to airborne organisms.

This is why we size systems around your process and target organisms, and why we recommend measuring performance. Our UV meters for process monitoring let you confirm that the intended irradiance reaches your target and keep a record for audit purposes.

Where can UV-C disinfection be used?

UV air disinfection

Reduce airborne contamination to keep air clean.

Browse air disinfection solutions

UV surface disinfection

Kill bacteria and viruses on surfaces to improve cleanliness.

Browse surface disinfection lamps

Enclosed UV disinfection

Safe and effective disinfection of items, tools and utensils.

Browse enclosed systems

Implementing UV-C safely

UV-C can damage eyes and skin, so installing equipment needs proper assessment of exposure risks, engineering controls, guarding, interlocks, operating procedures and training.

You should consider how workers might be exposed during normal operation, cleaning, maintenance and fault-finding. A system that is safe when fully enclosed may present a different risk if opened or accessed while running.

We support organisations assessing artificial UV sources with a UV safety and compliance package, UV risk management training, workplace radiation surveys and hazard awareness training. We also run a free UV safety webinar covering your legal obligations when operating artificial UV sources at work.

Frequently asked questions

What UV-C dose kills bacteria and viruses?

It depends on the organism and the reduction you need. Most vegetative bacteria reach a 90% reduction (D90) below 100 J/m², while bacterial spores and some viruses need several hundred. Salmonella enteritidis has a published D90 of 10 J/m² on surfaces, while Listeria monocytogenes has a D90 of 156 J/m². Each further log reduction needs the D90 dose to be applied again, so 99.9% needs roughly three times the D90.

What is a D90 value?

A D90 value is the UV-C dose, in J/m², needed to inactivate 90% of a microbial population. It is the standard way of comparing how sensitive different microorganisms are to UV-C.

Does UV-C kill Listeria?

Yes. UV-C damages the DNA of Listeria monocytogenes and prevents it replicating. The published D90 of 156 J/m² on surfaces is higher than for organisms such as Salmonella or E. coli, so systems targeting Listeria need to deliver a higher dose.

Does UV-C kill spores?

Yes, but spores are far more resistant than vegetative bacteria. Published D90 values for Bacillus spores in the tables above range from 144 to 743 J/m², so inactivating them needs a significantly higher dose or longer exposure.

Is UV-C effective against viruses?

Yes. UV-C damages viral DNA and RNA so the virus cannot replicate. D90 values vary widely, from a few J/m² for some airborne coronaviruses and phages to several hundred J/m² for adenoviruses on surfaces.

Does UV-C kill mould?

UV-C can inactivate mould cells and spores in suitable applications, but fungal spores are often more resistant than bacteria, and it does not destroy mycotoxins already present. It does not replace fixing the cause of mould growth, such as moisture, poor ventilation or water damage.

Can UV-C replace chemical disinfection?

UV-C does not replace cleaning, because it cannot remove soiling and only works where the light reaches. It is a valuable addition to a hygiene regime, giving rapid, chemical-free disinfection with no residues, and it can be measured and validated.

Can UV-C be used to disinfect people or skin?

No. UV-C can damage eyes and skin and must never be used to disinfect people, hands or skin. Equipment must be designed and operated so that workers and occupants are not exposed.

Is the dose in the table guaranteed in my facility?

No. The tables show indicative laboratory results, and conditions such as distance, shadowing, airflow and lamp age change the dose delivered. We recommend testing and validating performance in your own process, and we can help you plan and monitor this.

Talk to our UV-C disinfection specialists

Understanding the microorganism is the first step in choosing a disinfection strategy. Tell us about your process, your target organisms and your environment, and we will recommend a solution and arrange an online or onsite consultation.

Call us on +44 (0) 1564 200 826 or contact us to discuss your requirements.

Contact us to discuss your UV light requirements

Whether you’re already using UV and looking to learn more about safety, or looking to introduce a new process, we’d love to hear from you.

Get in touch

Speak to a member of our team

+44 (0) 1564 200 826