Call us on +44 (0) 1564 200 826

UV-C disinfection of Listeria monocytogenes

Listeria monocytogenes is one of the most persistent threats in food production. It survives in cold, damp conditions that stop most other pathogens, it can settle into hard-to-clean areas of a facility, and a single contamination event in a ready-to-eat product can lead to a recall, an outbreak investigation and lasting damage to your brand.

UV-C disinfection offers an additional, chemical-free layer of control. It inactivates Listeria by damaging its DNA, it acts within seconds to minutes, leaves no residue, and the dose delivered can be measured and recorded to support your food safety plan.

This guide explains where Listeria hides in a food facility, what dose of UV-C the published research says is needed to inactivate it, and how air, surface and enclosed UV-C systems can be used to support control. It is written for factory managers, food safety and quality managers, and hygiene and compliance teams in food production, and for catering managers in healthcare.

Listeria monocytogenes at a glance

TypeBacterium (vegetative, non-spore forming)
Where it growsAble to multiply at refrigeration temperatures
UV-C wavelength used254 nm
D90 dose (1-log, 90% reduction)156 J/m² on surfaces (Kim 2002)
Illustrative 3-log dose (99.9%)468 J/m²
Compared with other food pathogensHigher than Salmonella enteritidis (10 J/m²), E. coli (55 J/m²) and Staphylococcus aureus (66 J/m²)

What is Listeria monocytogenes?

Listeria monocytogenes is a bacterium found widely in the environment, including soil, water, decaying vegetation and the digestive tracts of animals. It can enter a food facility on raw materials, people, pallets, trolleys and equipment, and it survives well in the conditions common to food processing.

It causes listeriosis, an infection that is usually mild in healthy adults but can be serious for pregnant women and their unborn babies, newborns, older people and anyone with a weakened immune system.

Why Listeria is a problem in food production

Listeria stands out from other foodborne pathogens for several reasons.

It tolerates the cold. Most pathogens are held in check by refrigeration. Listeria can still multiply slowly at chill temperatures, which means products with a long refrigerated shelf life can allow it to grow.

It tolerates salt and other common controls. It withstands conditions that inhibit many other bacteria, making it harder to control through formulation alone.

It persists in the environment. Listeria can establish in harbourage sites within a facility and remain there for months or years, repeatedly contaminating products, which is why a single positive swab can point to a wider problem.

It is a particular risk for ready-to-eat foods. Foods eaten without further cooking, such as sliced meats, smoked fish, soft cheeses, prepared salads, sandwiches and chilled meals, give any surviving Listeria no further kill step before the consumer. Post-cook handling steps such as slicing, portioning and packing are common points of contamination.

UK and EU food law expects producers of ready-to-eat foods that may pose a Listeria risk to sample their processing areas and equipment, and customers and auditors increasingly expect a documented, risk-based environmental monitoring programme. UV-C can support the controls you put in place when swab results show a problem.

Listeria and healthcare

Hospitals, care homes and other healthcare settings serve food to some of the groups most at risk from listeriosis. For infection control and catering teams, this means careful control of chilled food storage and preparation areas, and of the surfaces, utensils and equipment used to prepare food for vulnerable patients and residents. UV-C can add a further control for catering equipment, utensils and chilled preparation areas.

Where Listeria hides: typical hot spots

Listeria favours cool, damp, hard-to-clean areas. The sites below are those most often associated with persistence in food facilities.

  • Drains and floors, particularly where water pools or floors are cracked, damaged or poorly drained.
  • Condensation and wet areas, including cold room ceilings, walls, drip trays and refrigeration units.
  • Conveyors and belts, including belt joins, rollers and the frames and supports beneath them.
  • Slicers, dicers, blenders and other equipment with complex parts, gaps and seals that are hard to dismantle and clean.
  • Knives, utensils and tools that move between areas and between tasks.
  • Trolleys, wheels, pallets and boxes that carry contamination between zones.
  • Packing and wrapping areas, where products are exposed after processing and before sealing.
  • Handwash stations, door handles and shared touch points.
  • Air in chilled production and packing areas, where airborne particles can settle on products and surfaces.

Cleaning remains the foundation of Listeria control. UV-C adds a measurable, chemical-free step on top of it, particularly for surfaces and items that move between zones and for repeated disinfection between cleaning cycles.

How UV-C inactivates Listeria

UV-C light at around 254 nm is absorbed by the DNA of Listeria monocytogenes. The energy damages the genetic material so the bacterium can no longer replicate or cause infection. Because the mechanism is physical rather than chemical, it leaves no residue and microorganisms do not become resistant to it in the way they can to some disinfectants.

UV-C dose requirements for Listeria

Dose (J/m²) is the irradiance reaching the target (W/m²) multiplied by the exposure time (seconds). The published D90 for Listeria monocytogenes on surfaces is 156 J/m². This is the dose needed to inactivate 90% of the population, a 1-log reduction.

Each further log reduction needs another D90 of dose. The table below shows the dose for each level of reduction, and how long this would take at three illustrative irradiance levels.

Log reductionReductionDose (J/m²)Time at 5 W/m²Time at 10 W/m²Time at 20 W/m²
1-log90%15631 seconds16 seconds8 seconds
2-log99%31262 seconds31 seconds16 seconds
3-log99.9%46894 seconds47 seconds23 seconds
4-log99.99%624125 seconds62 seconds31 seconds
5-log99.999%780156 seconds78 seconds39 seconds
6-log99.9999%936187 seconds94 seconds47 seconds

These are theoretical figures that assume a constant irradiance and a straight-line response. They show how dose, irradiance and time relate, not a guarantee of performance in a real installation.

How does Listeria compare with other organisms?

Listeria needs a higher dose than most other common foodborne bacteria. Its D90 of 156 J/m² is around 15 times that of Salmonella enteritidis (10 J/m²), nearly three times that of E. coli (55 J/m²) and over twice that of Staphylococcus aureus (66 J/m²). A system designed to control Listeria is therefore likely to give a good margin for these organisms as well, and this is why we usually design around Listeria in food applications.

Dose requirements for Listeria in air are not given in the published dataset we use. If air disinfection is part of your plan, we will discuss how it should be assessed for your environment.

Why the dose in your facility differs

Published values come from controlled laboratory tests. In a working facility, the dose that reaches Listeria depends on distance from the lamp, exposure time, lamp output and age, shadowing and surface condition, and on soiling and moisture.

Operating temperature matters too. UV-C lamp output is affected by temperature, which is important in chilled and cold areas, so equipment must be specified for the conditions in which it will operate.

We size systems around your process and measure the result, so you can demonstrate that the intended dose is reaching the target. Our UV meters for process monitoring support this.

UV-C solutions for Listeria control

We supply UV-C systems for the main routes by which Listeria spreads in a facility.

UV air disinfection

Reduce airborne contamination to keep air clean.

Browse air disinfection solutions

UV surface disinfection

Kill bacteria and viruses on surfaces to improve cleanliness.

Browse surface disinfection lamps

Enclosed UV disinfection

Safe and effective disinfection of items, tools and utensils.

Browse enclosed systems

What UV-C can and cannot do for Listeria

UV-C is a valuable additional control, and it works best when its limits are understood.

UV-C is line of sight. It only inactivates Listeria it reaches, so shadowed, rough or hidden areas may not receive the required dose.

It works best on clean surfaces. Soil, films and moisture can shield microorganisms, and Listeria that is established in a biofilm is harder to reach, so UV-C does not replace cleaning and should not be used as a substitute for it.

It supports, but does not replace, your wider controls. These include supplier controls, sanitation, zoning, temperature control and environmental monitoring.

It must be validated. Where a specific reduction is needed, performance should be confirmed under representative conditions, ideally alongside your environmental monitoring results.

Direct treatment of food products with UV-C is subject to specific regulatory requirements, so we focus on equipment, surfaces, packaging, tools and air. If you are considering any treatment of food itself, we recommend taking regulatory advice first.

Implementing UV-C safely

UV-C can damage eyes and skin, and must never be used to disinfect people, hands or skin. Any installation needs a proper assessment of exposure risk, engineering controls, guarding and interlocks, operating procedures and training, including during cleaning and maintenance.

We support food producers with a UV safety and compliance package, UV risk management training, workplace radiation surveys and hazard awareness training. We also run a free UV safety webinar covering the legal requirements for artificial UV sources in the workplace.

Frequently asked questions

Does UV-C kill Listeria?

Yes. UV-C light at around 254 nm damages the DNA of Listeria monocytogenes, preventing it from replicating. The published D90 is 156 J/m² on surfaces, so achieving higher log reductions means delivering multiples of that dose.

What UV-C dose is needed for Listeria?

The D90 for Listeria monocytogenes on surfaces is 156 J/m², a 90% reduction. A 3-log (99.9%) reduction needs roughly 468 J/m², and a 4-log (99.99%) reduction roughly 624 J/m². These are indicative laboratory figures, and the dose needed in practice should be validated for your process.

How long does it take UV-C to kill Listeria?

It depends on the irradiance reaching the target. Dose equals irradiance multiplied by time, so at 10 W/m² a 3-log reduction needs around 47 seconds, and at 20 W/m² around 23 seconds. Distance, lamp output and surface condition all affect the irradiance in your facility.

Is Listeria harder to kill with UV-C than Salmonella or E. coli?

Yes. Its published D90 of 156 J/m² is around 15 times that of Salmonella enteritidis and nearly three times that of E. coli, so a system designed for Listeria will normally also cover these.

Can UV-C remove Listeria biofilms?

UV-C should not be relied on to remove established biofilms. Biofilms and soiling shield organisms from UV-C, so surfaces should be cleaned first. UV-C is then an additional step on clean surfaces, rather than a substitute for cleaning.

Where should UV-C be used to control Listeria?

Common applications include air in chilled production and packing areas, worktables and conveyors, tools, utensils and knives, and packaging and items moving between zones. The right choice depends on where your swabs and risk assessment show Listeria is most likely to spread.

Can UV-C replace chemical sanitisers?

UV-C does not replace cleaning, and it only works where light reaches. It reduces reliance on chemicals for some applications, leaves no residue, and can be measured and validated.

Related microorganisms

Listeria is one of several organisms that UV-C can help control. See our guides to Salmonella, E. coli and Staphylococcus aureus, or return to the full list of microorganisms inactivated by UV-C, with D90 dose data for more than 90 bacteria, viruses and spores.

Talk to our UV-C specialists about Listeria control

Tell us about your facility, your products and where Listeria is a risk, and we will help you work out the dose you need and the right UV-C system to deliver it. We can arrange an online or onsite consultation.

Call us on +44 (0) 1564 200 826 or contact us to request a quotation.